NDT Services
Non-destructive testing support for evaluating materials, components and structures without compromising their intended use.
Maintaining structural integrity and operational reliability in high-stakes energy assets requires rigorous, non-invasive inspection methods. Dovaheights provides advanced Non-Destructive Testing (NDT) services designed to evaluate oilfield infrastructure, pressure vessels, pipelines, and mechanical components without halting operations or compromising material structure.
By combining certified ASNT/PCN inspection personnel with modern testing technologies, we deliver high-density, accurate asset data. Our structured NDT methodologies identify surface and volumetric anomalies early, ensuring compliance with international standards (such as ASME, API, and ISO) and helping operators make data-driven maintenance decisions with total confidence.
High-frequency sound waves evaluate internal material thickness and identify volumetric discontinuities within metals and composites. Ideal for measuring pipe wall thinning, lamination checking, and structural weld inspections.
Electromagnetic induction detects surface and near-surface micro-cracks in conductive materials. Highly effective for inspecting heat exchanger tubing, bolt holes, and complex surface geometries without removing protective coatings.
Magnetic fields paired with fine ferromagnetic particles reveal surface and slight sub-surface flaws in ferromagnetic materials. A reliable solution for structural welds, lifting equipment, and drill stem components.
Direct and remote optical assessment evaluating surface finish, alignment, structural deformation, and visible corrosion mechanisms. Serves as the foundational baseline inspection across all asset management frameworks.
Modern x-ray imaging utilizing digital detectors instead of physical film, producing instant, high-resolution profile imagery of internal components, piping welds, and insulated lines with drastically reduced radiation exposure.
Advanced electromagnetic technique that detects and measures the length and depth of surface-breaking cracks through thick paint or protective coatings without needing surface preparation.
Powerful magnetic saturation techniques used for high-speed corrosion detection and wall-loss mapping across bulk steel storage tank floors and large-diameter carbon steel pipelines.
Penetrating electromagnetic technology capable of measuring wall thickness through heavy thermal insulation, fireproofing, or marine growth (Corrosion Under Insulation - CUI) without insulation removal.
Multi-element ultrasonic transducers generate steerable, focused beams to create detailed cross-sectional 2D/3D visual maps of internal weld defects, replacing traditional radiography with faster, safer digital imaging.
Highly accurate ultrasonic diffraction technique offering exceptional precision in sizing sub-surface weld flaws, crack heights, and growth rates across heavy-wall pressure vessels.
Specialized electromagnetic inspection method designed for equal-sensitivity flaw detection across the full wall thickness of ferromagnetic tubing inside boilers, feedwater heaters, and heat exchangers.
Surface and near-surface examination of suitable ferromagnetic components for relevant discontinuities.
Electromagnetic inspection of suitable conductive materials and components where the method is applicable.
Application of additional specialist NDT methods where appropriate to the material, component and inspection objective.
Record inspection results and supporting information required for technical review and reporting.
Document inspection activities, results and applicable observations in the agreed reporting format.
Systematic visual examination of applicable components, structures, welds and equipment.
Use of ultrasonic inspection techniques for applicable thickness measurement and flaw detection requirements.
NDT support for applicable weld inspection requirements.
Inspection during applicable fabrication and manufacturing activities.
NDT support for ongoing asset integrity and maintenance programmes.
Inspection support during maintenance and repair activities.
Establish the component, material, inspection objective, suspected condition and applicable project requirements.
Select the NDT method based on material, geometry, defect type, accessibility, inspection objective and applicable requirements.
Review the applicable procedure, prepare the inspection area and confirm the required equipment and inspection conditions.
Carry out the selected NDT examination in accordance with the approved inspection procedure and project requirements.
Capture inspection measurements, observations and relevant supporting information for technical review.
Conventional NDT methods (such as UT, MPI, and VT) generally provide qualitative or basic quantitative checks suited for standard geometry inspections. Advanced NDT methods (such as PAUT, TOFD, and PEC) utilize automated digital probes, enabling higher-resolution imaging, digital data archival, defect sizing, and testing through insulation or coatings without dismantling equipment.
Yes. Many of our advanced NDT techniques—including Pulsed Eddy Current (PEC) and high-temperature Ultrasonic Testing—are non-intrusive and engineered to operate safely on live, high-temperature equipment, preventing costly facility turnarounds.
Our inspections follow internationally recognized codes (ASME Section V, API 510/570/653, ISO 9712). Inspection logs, digital flaw maps, and formal reports produced by our certified Level II/III technicians provide the necessary engineering documentation to satisfy regulatory audits and classification societies.
Get in Touch